IPP> MOD - missing and duplicate keyword value in "printer-st ate-reaso ns"

IPP> MOD - missing and duplicate keyword value in "printer-st ate-reaso ns"

Wagner,William bwagner at digprod.com
Fri Jan 22 11:31:48 EST 1999


Tom,

Your suggestion seems reasonable, except did we not want to use the more
general "marker-supply" term rather than "toner", which implies a particular
type of marker?

Bill Wagner

-----Original Message-----
From: Hastings, Tom N [mailto:hastings at cp10.es.xerox.com]
Sent: Friday, January 22, 1999 11:26 AM
To: ipp
Subject: IPP> MOD - missing and duplicate keyword value in
"printer-state-reaso ns"


There is a missing keyword and a duplicate in the  "printer-state-reasons"
attribute in the 11/16/1998 IPP/1.0 Model document:

There is no 'toner-empty' and 'marker-supply-low' appears twice with slight
different definitions.

Here is the 11/16/1998 "printer-state-reasons" keywords:

	'toner-low': The device is low on toner.
	'marker-supply-low': The device is low on marker supply (ink, paint,
etc.).
	'spool-area-full': The limit of persistent storage allocated for
spooling has been reached.
	'cover-open': One or more covers on the device are open.
	'interlock-open': One or more interlock devices on the printer are
unlocked.
	'door-open': One or more doors on the device are open.
	'input-tray-missing': One or more input trays are not in the device.
	'media-low': At least one input tray is low on media.
	'media-empty': At least one input tray is empty.
	'output-tray-missing': One or more output trays are not in the
device
	'output-area-almost-full': One or more output area is almost full
(e.g. tray, stacker, collator).
	'output-area-full': One or more output area is full. (e.g. tray,
stacker, collator)
	'marker-supply-low': The device is low on at least one marker
supply. (e.g. toner, ink, ribbon)
	'marker-supply-empty: The device is out of at least one marker
supply. (e.g. toner, ink, ribbon)
	'marker-waste-almost-full': The device marker supply waste
receptacle is almost full.
	'marker-waste-full': The device marker supply waste receptacle is
full.
	'fuser-over-temp': The fuser temperature is above normal.
	'fuser-under-temp': The fuser temperature is below normal.
	'opc-near-eol': The optical photo conductor is near end of life.
	'opc-life-over': The optical photo conductor is no longer
functioning.
	'developer-low': The device is low on developer.
	'developer-empty: The device is out of developer.
	'interpreter-resource-unavailable': An interpreter resource is
unavailable (i.e. font, form)

I propose that we delete the first 'marker-supply-low' and add
'toner-empty', so the first two lines would read:

	'toner-low': The device is low on toner.
	'toner-empty':  The device is out of toner.

Ok?

Tom Hastings
(310) 333-6413



More information about the Ipp mailing list