IPP> MOD - comments on Carl's Set and Admin operations regist ration pr

IPP> MOD - comments on Carl's Set and Admin operations regist ration pr

Hastings, Tom N hastings at cp10.es.xerox.com
Mon Jun 28 20:20:08 EDT 1999


One more question:

-----Original Message-----
From: kugler at us.ibm.com [mailto:kugler at us.ibm.com]
Sent: Wednesday, June 23, 1999 09:23
To: ipp at pwg.org
Cc: hastings at cp10.es.xerox.com; alimpich at us.ibm.com; longstaf at us.ibm.com
Subject: Re: IPP> MOD - comments on Carl's Set and Admin operations
registration proposal

snip...

3)  Add the following OPTIONAL operation attributes to the Shutdown-Printer
request:
"non-process-run-out" (boolean) specifies whether the printer should perform
an
NPRO (move the last printed sheet to the stacker) before shutting down.
"synchronize" (boolean) specifies whether to synchronize the checkpoint data
for
the current job with the pages that have actually printed.  If this
attribute is
supported, a value of true implies that the Printer will be able to resume
the
job at the point of synchronization when restarted.

TH7> If the "when" parameter is 'after-current' or 'after-all', wouldn't
these two operation attributes make sense to be 'true'?   Or are these two
attributes really independent of the "when" parameter?  If they aren't
independent, then maybe we should combine them with the "when" parameter?

snip...

    -Carl