I've posted the updated IPPGET Event Notification Delivery Method that is
REQUIRED for IPPFAX:

ftp://ftp.pwg.org/pub/pwg/ipp/new_NOT/ipp-notify-get-011017.pdf
ftp://ftp.pwg.org/pub/pwg/ipp/new_NOT/ipp-notify-get-011017.doc
ftp://ftp.pwg.org/pub/pwg/ipp/new_NOT/ipp-notify-get-011017-rev.pdf
ftp://ftp.pwg.org/pub/pwg/ipp/new_NOT/ipp-notify-get-011017-rev.doc

The -rev version show the revisions since the July 17, 2001 version.

It has all of the agreements reached at the August 1, IPP FAX meeting in
Toronto and the subsequent 3 telecon, August 11, 14, and 17.  See the
telecon and meeting notes for the list of the changes.

I'll send a .txt I-D later Friday.  Please send any comments to the mailing
list.  We'll also review at the IPPFAX WG meeting, next Wednesday, October
24 in San Antonio.

There are two issues:

	ISSUE 01:  Although we agreed to extend Job Creation operations to
support Event Wait Mode, it seems to be an unnecessary complication, since
the Printer MUST keep events for at least 15 seconds.  So OK NOT to add the
"notify-wait" (boolean) operation attribute to Job Creation operations and
NOT have to have Job Creation responses return Event Notification Groups (in
addition to returning Subscription Attribute Groups).

	ISSUE 02:  How unique do we need the "notify-recipient-uri" (uri)
URL now that the Printer doesn't use anything but the scheme in the URL to
match on?

Here are the major changes:

1. Removed the "notify-recipients-uri" operation attribute from
Get-Notifications, so no URI matching.

2. Changed "notify-subscription-id" (integer(1:MAX)) to
"notify-subscription-ids" (1setOf integer(1:MAX)); the client MUST supply
with at least one value.   Printer MUST support multiple-values.

3. Added "notify-sequence-numbers" (1setOf integer(1:MAX)) to be parallel
and be a floor to the Event Notifications sequence numbers returned.  The
client SHOULD supply.  Printer MUST support multiple-values.

4. In Event Wait Mode, each response is a full IPP response.

5. Moved "notify-get-interval" back to the operations attributes group in
the response.

6. Added 'successful-ok-events-complete to indicate that there will be no
more events for this Subscription object.

7. The  Printer MUST support Event Wait Mode.

8. The client can end Event Wait Mode (without closing the connection) by
sending "notify-wait" = 'false' any time.  The Printer can end Event Wait
Mode (without closing the connection) by returning "notify-get-internal"
operation attribute any time (including immediately).

9. Changed the lower limit for "ippget-event-life" from 1 to 15 seconds and
recommend 60 seconds to agree with the PWG Job Monitoring MIB (RFC 2707).