FIN Mail Archive: FIN> FW: Lint output on Finisher MIB

FIN> FW: Lint output on Finisher MIB

From: McDonald, Ira (IMcDonald@crt.xerox.com)
Date: Mon Nov 05 2001 - 19:42:22 EST

  • Next message: McDonald, Ira: "FIN> FW: Linted MIB index, by date"

    Hi folks,

    Thanks to Ray Casterline for finding this 'smilint' (like 'lint' for C)
    on the latest Finisher MIB, from the AT&T ACIRI site (I'll send the URL).

    I'm looking at these to suggest possible fixes or adjustments.

    Cheers,
    - Ira McDonald, consulting architect at Xerox
      High North Inc

    -----Original Message-----
    From: Ray Casterline [mailto:rcasterline@crt.xerox.com]
    Sent: Monday, November 05, 2001 2:21 PM
    To: Ira McDonald
    Subject: Here is Finisher Lint

    smilint output for ./Finisher-MIB

        Message Severities
          Severity
                      Count
     change recommended
                        3

                   Message Types
                    Type
                                         Count
     namelength-32-object (change recommended)
                                           3

    Messages:

    Finisher-MIB

       1: -- extracted from draft-ietf-printmib-finishing-12.txt
       2: -- at Tue Oct 9 06:06:32 2001

     730:
     731: finSupplyMediaInputMediaDimFeedDir OBJECT-TYPE

     731: change recommended - object identifier name
    `finSupplyMediaInputMediaDimFeedDir' longer than 32 characters

     732: SYNTAX Integer32 (-2..2147483647)
     733: MAX-ACCESS read-write
     734: STATUS current
     735: DESCRIPTION
     736: "This object provides the value of the dimension in the
     737: feed direction of the media that is placed or will be
     738: placed in this input device. Feed dimension measurements
     739: are taken parallel to the feed direction of the device and
     740: measured in finSupplyMediaInputDimUnits. If this input
     741: device can reliably sense this value, the value is sensed
     742: and is read-only access. Otherwise the value is read-write
     743: access and may be written by management or control panel
     744: applications. The value (-1) means other and specifically
     745: indicates that this device places no restrictions on this
     746: parameter. The value (-2) indicates unknown. "
     747: ::= { finSupplyMediaInputEntry 6 }
     748:
     749: finSupplyMediaInputMediaDimXFeedDir OBJECT-TYPE

     749: change recommended - object identifier name
    `finSupplyMediaInputMediaDimXFeedDir' longer than 32 characters

     750: SYNTAX Integer32 (-2..2147483647)
     751: MAX-ACCESS read-write
     752: STATUS current
     753: DESCRIPTION
     754: "This object provides the value of the dimension across the
     755: feed direction of the media that is placed or will be
     756: placed in this input device. The cross feed direction is
     757: ninety degrees relative to the feed direction on this
     758: device and measured in finSupplyMediaInputDimUnits. If
     759: this input device can reliably sense this value, the value
     760: is sensed and is read-only access. Otherwise the value is
     761: read-write access and may be written by management or
     762: control panel applications. The value (-1) means other and
     763: specifically indicates that this device places no
     764: restrictions on this parameter. The value (-2) indicates
     765: unknown. "
     766: ::= { finSupplyMediaInputEntry 7 }
    ...
     829:
     830: finSupplyMediaInputMediaThickness OBJECT-TYPE

     830: change recommended - object identifier name
    `finSupplyMediaInputMediaThickness' longer than 32 characters

     831: SYNTAX Integer32 (-2..2147483647)
     832: MAX-ACCESS read-write
     833: STATUS current
     834: DESCRIPTION
     835: "This object identifies the thickness of the input media
     836: processed by this document input subunit measured in
     837: micrometers. This value may be used by devices (or
     838: operators) to set up proper machine tolerances for the
     839: feeder operation. The value (-2) indicates that the media
     840: thickness is unknown or not used in the setup for this
     841: input subunit."
     842: ::= { finSupplyMediaInputEntry 14 }