From: Ira McDonald (blueroofmusic@gmail.com)
Date: Mon Nov 12 2007 - 22:29:16 EST
Hi folks, Monday (12 November 2007)
I've just posted one ZIP file to the PWG FTP server at:
ftp://ftp.pwg.org/pub/pwg/pdm/objects/skeleton-final-bugs.zip
which contains the following three files:
pdm-bugs.txt - appended in plaintext below
- detailed bug report
skeleton-final-tc.mib
- first half of PDM MIB
skeleton-final-mib.mib
- second half of PDM MIB
Rick - Some of these are just capitalization in the textual conventions.
But the synonyms for TruthValue (SNMP boolean) are illegal and won't do
(they'll fail IETF MIB Doctors review, so we shouldn't use them). I
quickly gave up on the main MIB module, because the DEFVAL clauses
use the wrong (single) quote marks and appear in the wrong order. SNMP
OBJECT-TYPE macro does NOT allow out-of-order clauses. To fix the enum
names, use a 'diff' against skeleton-final-tc.mib and then fix source
classes.
Cheers,
- Ira
-- Ira McDonald (Musician / Software Architect) Chair - Linux Foundation Open Printing WG Blue Roof Music / High North Inc PO Box 221 Grand Marais, MI 49839 work: +1-906-494-2434 home: +1-906-494-2697 email: blueroofmusic@gmail.com------------------------------------------------------------------------ [pdm-bugs.txt]
*** skeleton-final-tc.mib ***
* Global - change "SYNTAX integer" --> "SYNTAX INTEGER" (ASN.1 base type - ALL types MUST start with an uppercase letter)
* PdmPwrStCommAvailableTC - named number "True" must begin lowercase - illegal TC - synonym for TruthValue (SNMP boolean)
* PdmDisplaySettingVideoMuteTC - illegal TC - synonym for TruthValue (SNMP boolean)
* PdmDisplaySettingDisplayModeTC - named number "Zoom" must begin lowercase
* PdmDisplaySettingColorTempTC - expected a string, got 6300
* PdmLightSourceBrightSettingTC - named number "High" must begin lowercase - invalid number for other(4)
* PdmLightSourceLampStatusTC - named number "Alive" must begin lowercase - illegal TC - synonym for TruthValue (SNMP boolean)
*** skeleton-final-mib.mib ***
* PdmFirmwareUpgradeModeTC - change "PdmFirmwareUpgradeModeTC" -> "PdmCtlrFirmwareUpgradeableTC" - line 14: not defined in PWG-PROJECTOR-DISPLAY-TC
* PdmPostStatusTC - change "PdmPostStatusTC" -> "PdmCtlrPostStatusTC" - line 14: not defined in PWG-PROJECTOR-DISPLAY-TC
* pdmDeviceTypes - line 70: Conflicting registrations "pdmDeviceProjector" and "pdmGeneralProductName" - reuse of "{ pdmMIBObjects 1 }"
* pdmGeneral - line 94: expected ::=, got {
* pdmGeneralProductName - line 101: expected STATUS, got DEFVAL - line 106: invalid character in binary or hexadecimal string - change single quotes (binary) to double quotes (string) in DEFVAL - line 107: Conflicting registrations "pdmDeviceProjector" and "pdmGeneralProductName" - reuse of "{ pdmMIBObjects 1 }"
* and much more of the same - SNMP MIB clauses MUST NOT be in wrong order - OIDs MUST NOT be reused - names longer than 31 characters are dangerous - type (SYNTAX) names MUST NOT start with lowercase (e.g., "pdmCtlrFirmwareUpgradeableTC")
------------------------------------------------------------------------