Printer Services Mail Archive: Re: PS> Minutes of PSI teleco

Re: PS> Minutes of PSI telecon on 6 July

From: Masanori ITOH (ito@src.ricoh.co.jp)
Date: Mon Jul 12 2004 - 03:58:04 EDT

  • Next message: McDonald, Ira: "PS> FW: Interim draft of PSI spec from Dave Hall"

    Hi Mr. McDonald,

    I found my comment is strange.

    You mentioned 'RegisterTargetDevice' method has 'NotifyEvents'
    instead of 'PrinterEvents' as follows.

        4.9 PrinterEvents will be replaced with NotifyEvents
            (to allow subscription to all classes of events) in
            RegisterTargetDevice

    So is '4.10' as to 'SendTargetDeviceNotification' method ?

    But 'PrinterEvents' doesn't exist in 'SendTargetDeviceNotification'
    method.

    I don't know what you mean.
    Would you tell me that in detail ?

    Cheers,
    Masa.

    -----------------------
    Masanonri 'MASA' Itoh
    RICOH Co., Ltd. Software R&D Center

     
            
    --------------------------------------------------------
    Masanori ITOH wrote on Mon, 12 Jul 2004 14:17:50 +0900

    |Hi Mr. McDonald,
    |
    |Now I'm modifying WSDLs as decided in the last telecon.
    |And I have two questions.
    |
    |Do you mean this 'SendTargetDeviceNotification' is the return value of
    |'RegistertargetDevice' method ?
    |
    | 4.10 SubunitEvents and VendorEvents (missing parameters)
    | will be added (in addition to existing PrinterEvents) to
    | SendTargetDeviceNotification
    | (to add support for detailed Subunit events such as
    | 'InputMediaSupplyLow' and Vendor events from different
    | non-Printer objects)
    |
    |If so, the return parameter is named as 'sendTargetDeviceNotifications'
    |(the plural) ?
    |If not, is is for 'SendTargetDeviceNotification' method (5.6.11) ?
    |
    |I think it it as to 'RegistertargetDevice' method because
    |there is 'PrinterEvents' in 'SendTargetDeviceNotification' method.
    |
    |And this is the other question.
    |If my opinion is correct, how do you define 'sendTargetDeviceNotifications' ?
    |It consists of three events, PrinterEvents, SubunitEvents, and VendorEvents.
    |Do you mean new complex schema type for them is defined like 'NotifyEvents' ?
    |
    |Cheers,
    |Masa.
    |
    |-----------------------
    |Masanonri 'MASA' Itoh
    |RICOH Co., Ltd. Software R&D Center
    |
    |
    |Mr. McDonald, Ira wrote on Wed, 7 Jul 2004 11:20:19 -0700
    |
    |------------------------------------------------
    |
    |Hi,
    |
    |Comments or corrections are welcome.
    |
    |
    |(1) target namespace will be added to Events schema
    | of PWG Semantic Model/1.0, e.g.,
    |
    |<xsd:schema targetNamespace="http://www.pwg.org/schemas/sm/1.0/"
    | xmlns:xsd="http://www.w3.org/2001/XMLSchema"
    | xmlns="http://www.pwg.org/schemas/sm/1.0/">
    |
    |(2) UnsupportedElements will be corrected to be defined
    | the same as PWG SM/1.0 schema and IPP/1.1 (RFC 2911)
    | (consistent semantics and interworking of gateways)
    |
    |(3) Jerry Thrasher's issues in latest draft:
    |
    | 3.1 interfaceIdentifier will be defined in PSI spec,
    | to avoid normative dependency on WSDL
    |
    | 3.2 callbackInterval will be defined in to PSI spec,
    | to avoid normative dependency on IPP GET
    | (and conformance requirement vis-a-vis Job History
    | time will be removed, due to weak rationale)
    |
    | 3.3 eventNumber parameter SHOULD be renamed (to align
    | with WIMS and IPP) to notifySequenceNumber
    |
    |** DAVE ** I just found a bug in our definition below **
    |
    | Since SendXxxNotification methods can transfer
    | one or _more_ events in a single notification,
    | the correct semantic is that the renamed parameter
    | is the number of this notification message (NOT
    | the number of one of the events in the message).
    |
    | 3.4 eventID in section 5.6.11 will replaced with the
    | correct notifySequenceNumber
    |
    | 3.5 normative references
    | - moved WS-Addressing and WS-Security to informative
    | - kept W3C Notes on WSDL/1.1 and SOAP/1.1 in the
    | normative references and will add the phrase
    | "defacto industry standard"
    |
    | (because all existing tools only support these
    | defacto standards - very little support for SOAP/1.2
    | has been shipped or deployed - no support for the
    | future _incompatible_ WSDL/2.0 has been shipped)
    |
    | 3.6 documentFilterElements will be marked OPTIONAL
    |
    | 3.7 all of Masanori Itoh's suggested changes were also
    | made by Jerry Thrasher and approved in the telecon
    |
    |4. Ira McDonald's changes for events:
    |
    | 4.1 JobEvents definition will be corrected in
    | FetchNextJob
    |
    | 4.2 callbackInterval - see 3.2 above
    | FetchNextJob
    |
    | 4.3 DocumentEvents definition will be corrected in
    | FetchNextDocumentByPull
    |
    | 4.4 callbackInterval - see 3.2 above
    | FetchNextDocumentByPull
    |
    | 4.5 DocumentEvents - see 4.3 above
    | FetchNextDocumentByValue
    |
    | 4.6 callbackInterval - see 3.2 above
    | FetchNextDocumentByValue
    |
    | 4.7 JobEvents (missing parameter) will be added to
    | SendJobNotification
    |
    | 4.8 DocumentEvents (missing parameter) will be added to
    | SendDocumentNotifications
    |
    | 4.9 PrinterEvents will be replaced with NotifyEvents
    | (to allow subscription to all classes of events) in
    | RegisterTargetDevice
    |
    | 4.10 SubunitEvents and VendorEvents (missing parameters)
    | will be added (in addition to existing PrinterEvents) to
    | SendTargetDeviceNotification
    | (to add support for detailed Subunit events such as
    | 'InputMediaSupplyLow' and Vendor events from different
    | non-Printer objects)
    |
    |(5) ** Significant Change **
    |
    | 5.1 Entire current Std Print System Events spec will be
    | incorporated as an appendix into the PSI spec
    | (to avoid new normative dependencies for PSI)
    |
    | 5.2 At some future date, a PWG Std Imaging System Events
    | spec may be developed as a PWG 'dictionary' standard
    |
    |(6) ** Last Call **
    | - PSI/1.0 and Events schema will enter PWG 'last call'
    | no later than 26 July, to complete at the PWG Plenary
    | on Wednesday 18 August in Montreal
    |
    |Cheers,
    |- Ira
    |
    |Ira McDonald (Musician / Software Architect)
    |Blue Roof Music / High North Inc
    |PO Box 221 Grand Marais, MI 49839
    |phone: +1-906-494-2434
    |email: imcdonald@sharplabs.com