PWG Mail Archive: PWG> Change Document

PWG> Change Document

Chris Wellens (chrisw@iwl.com)
Mon, 9 Dec 1996 09:24:30 -0800 (PST)

According to the Guide for Internet Standards Writers
<draft-ietf-stdguide-ops-01.txt>, in the "Document
Checklist", we are required to describe the
differences from previous versions in our new
document.

Here is a first past at a list of the changes between
RFC1759 and the new draft document:

List of Changes to RFC 1759 (DRAFT Revision 120796)

RFC1759 had 9 mandatory groups and 9 optional groups.
Now there are 11 optional groups. The two new groups are:
prtInputSwitchingGroup and prtAuxiliarySheetGroup

Following are the New Textual Conventions (not present in
RFC1759):

PrtSupplementaryPageContextTC
PrtPrintOrientationTC
PrtCoverStatusTC
PrtGeneralResetTC
PrtChannelStateTC
PrtChannelTypeTC
PrtInterpreterLangFamilyTC
PrtOutputTypeTC
PrtOutputStackingOrderTC
PrtOutputPageDeliveryOrientationTC
PrtMarkerMarkTechTC
PrtMarkerCounterUnitTC
PrtMarkerSuppliesTypeTC
PrtMarkerSuppliesSupplyUnitTC
PrtMarkerSuppliesClassTC
PrtMarkerColorantRoleTC
PrtMediaPathMaxSpeedPrintUnitTC
PrtMediaPathTypeTC
PrtInterpreterDefaultOrientationTC
PrtInterpreterTwoWayTC
PrtConsoleColorTC
PrtAlertSeverityLevelTC
PrtAlertTrainingLevelTC
PrtAlertGroupTC
PrtAlertCodeTC

In The General Printer Group:

prtGeneralReset was INTEGER and is now a textual
convention.

Two new objects were added:

prtGeneralStartupPage PresentOnOff
prtGeneralBannerPage PresentOnOff

prtCoverStatus is now a Textual Convention

The Auxiliary Sheet Group (a new optional group)

prtGeneralStartupPage
prtGeneralBannerPage

-- The Input Group

--
        prtInputType was INTEGER and is now a textual
convention.

prtInputDimUnit was MediaUnit and is now a textual convention.

prtInputCapacityUnit was CapacityUnit and is now a textual convention

prtInputStatus was SubUnitStatus and is now a textual convention

Three new objects were added:

prtInputManualFeedTimeout Integer32 prtInputAutoSwitch PresentOnOff prtInputNextIndex Integer32

The Input Switching Group (a new optional group)

prtInputManualFeedTimeout prtInputAutoSwitch prtInputNextIndex

--The Output Group

prtOutputType was INTEGER and is now a textual convention

prtOutputCapacityUnit was CapacityUnit, and is now a textual convention

prtOutputStatus was SubUnitStatus, and is now a textual convention

prtOutputDimUnit was MediaUnit, and is now a textual convention

prtOutputStackingOrder was INTEGER, and is now a textual convention

prtOutputPageDeliveryOrientation was INTEGER, and is now a textual convention

-- The Output Features Group

--
prtOutputStackingOrder was OBJECT-TYPE and is now a textual
convention

-- The Marker Group

prtMarkerMarkTech was INTEGER, and is now a textual convention

prtMarkerCounterUnit was INTEGER, and is now a textual convention

prtMarkerStatus was SubUnitStatus and is now a textual convention

-- The Marker Colorant Group

prtMarkerColorantRole was INTEGER, and is now a textual convention

- The Media Path Group

prtMediaPathIndex Integer32, and is now a textual convention

prtMediaPathMaxSpeedPrintUnit INTEGER, and is now a textual convention

prtMediaPathType INTEGER, and is now a textual convention

prtMediaPathStatus SubUnitStatus and is now a textual convention

- The Channel Group changed its name! New name is "The Print Job Delivery Channel Group"

prtChannelType was INTEGER, and is now a textual convention

prtChannelStatus was SubUnitStatus and is now a textual convention

One new object was added: PrtChannelInformation DisplayString

prtChannelState was OBJECT-TYPE and is now a textual convention

-- The Console Group

prtConsoleColor was INTEGER, and is now a textual convention

-- The Alerts Group

prtAlertSeverityLevel was INTEGER, and is now a textual convention

prtAlertTrainingLevel was INTEGER, and is now a textual convention

prtAlertGroup was INTEGER, and is now a textual convention

prtAlertCode was INTEGER, and is now a textual convention

The Alert Time Group is missing its heading in the revised document.