Web-based Imaging Management Services: RE: WIMS> SendReport

RE: WIMS> SendReport - multiple legacy devices

From: McDonald, Ira (imcdonald@sharplabs.com)
Date: Thu Aug 12 2004 - 10:08:21 EDT

  • Next message: McDonald, Ira: "WIMS> Posted PrtViews schema v0.30 (12 August 2004)"

    Hi Harry,
     
    You didn't read your change logs. SendReport has been renamed
    to SendReports (plural) and sends a _sequence_ of Report instances,
    one for _each_ value of ActionTargetURIs. Each Report instance
    contains the PlanStatus element, which contains PlanLastError,
    which is the exact full set of SNMPv2/v3 error codes (e.g.,
    'ReadOnly' or 'WrongEncoding'). One of the values of is also
    'NoError' (i.e., success). Either the presence of the optional element
    PlanLastError with 'NoError' or the absence of PlanLastError indicates
    success of the action for the particular target agent URI.
     
    OK?
     

    Ira McDonald (Musician / Software Architect)
    Blue Roof Music / High North Inc
    PO Box 221 Grand Marais, MI 49839
    phone: +1-906-494-2434
    email: imcdonald@sharplabs.com

    -----Original Message-----
    From: owner-wims@pwg.org [mailto:owner-wims@pwg.org]On Behalf Of Harry Lewis
    Sent: Wednesday, August 11, 2004 2:26 PM
    To: wims@pwg.org
    Subject: WIMS> SendReport - multiple legacy devices

    Question related to constructing SendReport for more than one legacy device
    by the WIMS proxy...
    Using Ira's Schedule example, below...

    To find out the status of a print device with a legacy
    SNMP manager using a WIMS Proxy, specify in a Schedule
    a GetElements action as follows:

    ActionTargetURIs = "snmp://example.com"

    ActionTargetObjects = (sequence of)

     ActionManagedEntityType = "Device"
       (generic Device object planned for WIMS)
     ActionManagedEntityURI = "*"
       (wildcard for any device at target agent)

    ActionRequestedElements = (sequence of)

     ActionRequestedElement = "pwg-sm:PrtViewDeviceStatus"
       (includes every interesting HR MIB state attribute)

     ActionRequestedElement = "pwg-sm:PrtViewGeneralStatus"
       (interesting state attributes from PrtGeneralTable)

    ActionParameters (omitted, no vendor extensions needed)

    1. Assume ActionTargetUIRs is a LIST?
        ActionTargetURIs = "snmp://example1.com"; "snmp://example2.com";
    "snmp://example3.com"...

    2. Then, in the SendReport... how is the status (what we are monitoring in
    this example) of device "example1" distinguished from the status of device
    "example2 or 3"?
        Is it simple by the ReportSourceURI (multiple - 3 in this case) reports
    are returned in the SendReport... each with a different source URI
    (snmp://examplex.com)
        or is the ReportSequenceNumber supposed to correlate, somehow to the
    Schedule in helping correlate values to a particular TargetURI (monitored
    device)?

    An example of very basic Schedule and SendReport for WIMS Proxy monitoring 3
    devices for one or two elements would be very useful!
    ----------------------------------------------