P1394> connection for Function or Service

P1394> connection for Function or Service

Hitoshi Sekine hitoshis at MICROSOFT.com
Fri Oct 16 14:55:37 EDT 1998


> A larger issue with "current PC OS" implementation may be how
> many outstanding requests can be supported at once by the SBP-2
> driver.

I agree that it is a large issue with the implementation.  But, it is not
clear to me that the SBP-2 is required to handle multiple logins or
connections.  Who cases multiple connections per a single login?  I think we
should be able to handle multiple connection on a single login or multiple
logins.  These implementations are very different.

Thanks,
Hitoshi

-----Original Message-----
From: Greg Shue [mailto:gregs at sdd.hp.com]
Sent: Friday, October 16, 1998 8:40 AM
To: Nagasaka.Fumio at exc.epson.co.jp
Cc: p1394 at pwg.org
Subject: Re: P1394> connection for Function or Service


> However, each service requires a multiplexed connection and
> each connection requires flow control and send/receive queues.

Whether we multiplex connections over a login or have separate
logins, each service is accessed over a connection, and each
connection requires flow control and send/receive queues.
This is a non-issue in the decision.

A larger issue with "current PC OS" implementation may be how
many outstanding requests can be supported at once by the SBP-2
driver.

-- 
Greg Shue
Hewlett-Packard Company
All-in-One Division			        gregs at sdd.hp.com
----------------------------------------------------------------



More information about the P1394 mailing list