PMP> prtAlertTime

PMP> prtAlertTime

Randy Turner rturner at sharplabs.com
Thu Apr 17 14:19:27 EDT 1997


If the system is unable to report the current time, then it could just
report
'sysUptime" from MIB-II  (which is mandatory BTW).


Randy


Bob Pentecost wrote:


> I have two items. The first is the need for clarification and the
> second is
> an editorial matter.
>
> When the object prtAlertTime was changed to a mandatory object,
> there was
> some discussion as to the value that would be returned if the device
> was
> unable to report the time. It was agreed that there was a way to
> report
> "Unknown" but no one knew the value. What is the value and should
> that be
> added to the MIB? (Note: Please don't restart the discussion about
> whether
> or not the device should know the time.)
>
> On page 56:
>           prtAlertTime             (Optional) the value of sysUpTime
> at
>                                    the time of the removal of the
> binary
>                                    change event from the alert
> table.
> Since this is no longer an optional object, "(Optional)" should be
> removed.



More information about the Pmp mailing list