PMP> RE: FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerS uppliesUn itTC'

PMP> RE: FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerS uppliesUn itTC'

McDonald, Ira imcdonald at sharplabs.com
Sun Nov 19 16:30:55 EST 2000


Hi Dennis,

YES - for 'prtInputMaxCapacity' I'll return 100, as you say.
Products that don't KNOW their actual capacity but only their
relative level really do NEED this 'percent' extension.

I have found email from Xerox and FujiXerox implementors in my
own archives more than two years ago asking for this exact
extension to capacity/level objects.  We did nothing about
it at the time because the Printer MIB v2 was dead in the
water for over two years.

So what if capacity is uninformative.  The levels ARE.

Cheers,
- Ira McDonald, consulting architect at Xerox and Sharp
  High North Inc

-----Original Message-----
From: Dennis Carney [mailto:dcarney at us.ibm.com]
Sent: Friday, November 17, 2000 11:57 AM
To: 'pmp at pwg.org'; 'fin at pwg.org'
Cc: imcdonald at sharplabs.com
Subject: FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and
'PrtMarkerSuppliesUn itTC'


Ira,

What are you going to return for prtInputMaxCapacity when
prtInputCapacityUnit is 'percent'? 100?  The same capacity unit is used for
both max capacity and current level, and 'percent' fits one but not the
other.

Dennis Carney
IBM Printing Systems
---------------------- Forwarded by Dennis Carney/Boulder/IBM on 11/17/2000
12:56 PM ---------------------------

"McDonald, Ira" <imcdonald at sharplabs.com>@pwg.org on 11/17/2000 12:25:50 PM

Sent by:  fin-owner at pwg.org


To:   "'pmp at pwg.org'" <pmp at pwg.org>, "'fin at pwg.org'" <fin at pwg.org>
cc:
Subject:  FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and
      'PrtMarkerSuppliesUn itTC'



Hi,

Implementors here at Sharp have found a serious problem with
'prtInputCurrentLevel', 'prtOutputRemainingCapacity' and
'prtMarkerSuppliesLevel'.

Their related units objects need 'percent(19)' added to
allow reporting of RELATIVE levels (often the only
information known from sensors).

- 'PrtCapacityUnitTC' should have 'items(18)' (per Ron B
  and Harry L) and 'percent(19)' added
- 'PrtMarkerSuppliesSupplyUnitTC' should have 'percent(19)'
  added

BOTH of these textual conventions should also have 'other(1)'
and 'unknown(2)' added - this would provide short-term
relief to the NEXT product team that finds a missing unit
AFTER the Printer MIB v2 is published as an RFC.

Cheers,
- Ira McDonald, consulting architect at Sharp
  High North Inc





More information about the Pmp mailing list