PMP Mail Archive: PMP> Disassociations

PMP> Disassociations

Gail Songer (Gail.Songer@eng.efi.com)
Wed, 5 Mar 1997 13:10:12 -0800

If hrPrinterStatus is idle,printing or warmup, then hrdeviceStatus must be
either running or warning. If hrPinterStatus is unknown, then hrDeviceStatus
must be unknown.

If hrDeviceStatus is warning then hrPrinterDetectedErrorState must be either
lowPaper 80, lowToner 20, or serviceRequested 01. If hrDeviceStatus is down
then hrPrinterDetectedErrorState must be either doorOpen 08, jammed 04, offline
02, noPaper 40, or noToner 10.

Or in other words:

hrPrinterStatus hrDeviceStatus hrPrinterDetectedErrorState
---------------------------------------------------------------------------
other
unknown<- - - - - - -> unknown
testing
down 0x08 0x04 0x02 0x40 0x10
idle \
printing >- - - - -\ running
warmup / / warning 0x80 0x20 0x01

Given alert.pdf, the following hrDeviceStatus states have been disassociated
with hrPrinterDetectedErrorState:

condition company hrDeviceStatus hrPrinterStatus ErrorState
---------------------------------------------------------------------------
Input Tray Missing 6 running idle 40
Tray Empty w/o Demand 5 down other 01
Tray Empty with Demand 5 down other 01
Paper Jam 5 down other 01
Output Bin Full 2 down other 01
Output Bin Full 5 down other 01
Toner Low Warning 2 down other 20
Toner Cartridge Missing 5 down other 01
Toner Cartridge Missing 6 running other 0a
Cover Open 5 down other 01

Additionally, the following is questionable:
---------------------------------------------------------------------------
Toner Cartridge Missing 6 running other

-- 

Gail Songer Electronics For Imaging gail.songer@eng.efi.com 2855 Campus Drive (415) 286-7235 San Mateo, CA 94403